The performance of a showerhead arrangement of film cooling in the leading edge region of a first stage nozzle guide vane was experimentally and numerically evaluated. A six-vane linear cascade was tested at an isentropic exit Mach number of Ma2s = 0.42, with a high inlet turbulence intensity level of 9%. The showerhead cooling scheme consists of four staggered rows of cylindrical holes evenly distributed around the stagnation line, angled at 45° towards the tip. The blowing ratios tested are BR = 2.0, 3.0 and 4.0. Adiabatic film cooling effectiveness distributions on the vane surface around the leading edge region were measured by means of Thermochromic Liquid Crystals technique. Since the experimental contours of adiabatic effectiveness showed that there is no periodicity across the span, the CFD calculations were conducted by simulating the whole vane. Within the RANS framework, the very widely used Realizable k-ε (Rke) and the Shear Stress Transport k-ω (SST) turbulence models were chosen for simulating the effect of the BR on the surface distribution of adiabatic effectiveness. The turbulence model which provided the most accurate steady prediction, i.e. Rke, was selected for running Detached Eddy Simulation at the intermediate value of BR = 3. Fluctuations of the local temperature were computed by DES, due to the vortex structures within the shear layers between the main flow and the coolant jets. Moreover, mixing was enhanced both in the wall-normal and spanwise direction, compared to RANS modeling. DES roughly halved the prediction error of laterally averaged film cooling effectiveness on the suction side of the leading edge. However, neither DES nor RANS provided the expected decay of effectiveness progressing downstream along the pressure side, with 15% overestimation of ηav at s/C =0.2.
Skip Nav Destination
ASME Turbo Expo 2016: Turbomachinery Technical Conference and Exposition
June 13–17, 2016
Seoul, South Korea
Conference Sponsors:
- International Gas Turbine Institute
ISBN:
978-0-7918-4980-4
PROCEEDINGS PAPER
Comparison of RANS and DES Modeling Against Measurements of Leading Edge Film Cooling on a First-Stage Vane
S. Ravelli,
S. Ravelli
University of Bergamo, Dalmine, Italy
Search for other works by this author on:
G. Barigozzi
G. Barigozzi
University of Bergamo, Dalmine, Italy
Search for other works by this author on:
S. Ravelli
University of Bergamo, Dalmine, Italy
G. Barigozzi
University of Bergamo, Dalmine, Italy
Paper No:
GT2016-57567, V05CT12A009; 13 pages
Published Online:
September 20, 2016
Citation
Ravelli, S, & Barigozzi, G. "Comparison of RANS and DES Modeling Against Measurements of Leading Edge Film Cooling on a First-Stage Vane." Proceedings of the ASME Turbo Expo 2016: Turbomachinery Technical Conference and Exposition. Volume 5C: Heat Transfer. Seoul, South Korea. June 13–17, 2016. V05CT12A009. ASME. https://doi.org/10.1115/GT2016-57567
Download citation file:
22
Views
Related Proceedings Papers
Related Articles
Comparison of RANS and Detached Eddy Simulation Modeling Against Measurements of Leading Edge Film Cooling on a First-Stage Vane
J. Turbomach (May,2017)
Stress-Blended Eddy Simulation of Coherent Unsteadiness in Pressure Side Film Cooling Applied to a First Stage Turbine Vane
J. Heat Transfer (September,2018)
Related Chapters
Cavitating Structures at Inception in Turbulent Shear Flow
Proceedings of the 10th International Symposium on Cavitation (CAV2018)
A Nonlinear Power Control Strategy for Ultra-High Voltage Tie Line
International Conference on Electronics, Information and Communication Engineering (EICE 2012)
Two Advanced Methods
Applications of Mathematical Heat Transfer and Fluid Flow Models in Engineering and Medicine