0
TECHNICAL PAPERS

Weight Sensation in Virtual Environments Using a Haptic Device With Air Jets

[+] Author and Article Information
Hakan Gurocak

Manufacturing Engineering, Washington State University, Vancouver 14204, NE Salmon Creek Ave., Vancouver, WA 98686

Sankar Jayaram, Benjamin Parrish, Uma Jayaram

School of Mechanical and Materials Engineering, P.O. Box 642920, Washington State University, Pullman, WA 99164-2920

J. Comput. Inf. Sci. Eng 3(2), 130-135 (Jun 30, 2003) (6 pages) doi:10.1115/1.1576808 History: Received June 01, 2002; Revised February 01, 2003; Online June 30, 2003
Copyright © 2003 by ASME
Your Session has timed out. Please sign back in to continue.

References

Angster, S., and Jayaram, S., 1997, “Open Architecture Framework for Integrated Virtual Product Development Systems,” Int. J. of Virtual Reality, 3 (1).
Burdea, G., 1996, Force and Touch Feedback for Virtual Reality, John Wiley and Sons, Inc.
Millman, P. et al., 1993, “Design of a High Performance Haptic Interface to Virtual Environments,” IEEE Virtual Reality Annual Int. Symp. (VRAIS), IEEE, New York.
Salcudean, S., and Vlaar, T., 1994, “On the Emulation of Stiff Walls and Static Friction With a Magnetically Levitated Input/Output Device,” Proc. of ASME WAM, DSC-Vol. 55-1.
Buttolo, P., and Hannaford, B., 1995, “Pen-Based Force Display for Precision Manipulation in Virtual Environments,” IEEE Virtual Reality Annual Int. Symp. (VRAIS), IEEE, New York.
Massie, T., and Salisbury, K., 1994, “The PHANToM Haptic Interface: A Device for Probing Virtual Objects,” ASME Winter Annual Meeting, DSC-Vol. 55-1.
Lindemann, R., and Tesar, D., 1989, “Construction and Demonstration of a 9-String 6dof Force Reflecting Joystick for Telerobotics,” Proc. of NASA Int. Conf. on Space Telerobotics, 4 .
Ishii, M., and Sato, M., 1994, “Force Sensation in Pick-and-Place Tasks,” Proc. of ASME WAM, DSC-Vol. 55-1.
Jacobsen, S. et al., 1991, “High Performance, Dexterous, Telerobotic Manipulator with Force Reflection,” Intervention/ROV’91, Hollywood, FL.
Burke, J., 1994, “Exoskeleton Master Arm, Wrist and End Effector Controller With Force-Reflecting Telepresence,” Technical report AL/CF-TR-1994-0146, Odetics Inc., Anaheim, CA.
EXOS Co., 1995, “Sensing and Force Reflecting Exoskeleton (SAFIRE) Specifications,” Company brochure, Woburn, MA.
Gomez, D., et al., 1994, “The Second-Generation Rutgers Master (RM-II),” The Third Int. Conf. on Automation Tech., Taiwan.
Colgate J. E., 1986, “The Design of a Dynamics Measuring Device,” Dep. of Mech. Eng., M.S. Thesis, MIT, Jan.
Murray, W. R., 1988, “Essential Factors in Modeling the Modulation of Impedance About the Human Elbow,” Ph.D. Thesis, Dep. of Mech. Eng., MIT.
Xu,  Y., Hunter,  I. W., Hollerbach,  J. M., and Bennett,  D. J., 1991, “An Airjet Actuator System for Identification of the Human Arm Joint Mechanical Properties,” IEEE Trans. Biomed. Eng., 38(11), Nov..
Burton, T. D., 1994, Introduction to Dynamic System Analysis, McGraw Hill, Inc., pp. 92–103.
Roberson, J. A., and Crowe, C. T., 1993, Engineering Fluid Mechanics, 5th ed., Houghton Mifflin, Princeton, N.J.
Charpentier,  A., 1891, “Analyze Experimentale de Quelques Elements de la Sensation de Poids [Experimental Study of Some Aspects of Weight Perception],” Archives de Physiologie Normales et Pathologiques, 1 (3), pp. 122–135.
Ellis,  R. R., and Lederman,  S. J., 1993, “The Role of Haptic Versus Visual Volume Cues in the Size-Weight Illusion,” Percept. Psychophys., 53(3), pp. 315–324.
Vardeman, S., and Jobe, J. M., 2001, Basic Engineering Data Collection and Analysis, Thomson Learning, Pacific Grove, CA.

Figures

Grahic Jump Location
AirGlove. (a) Air jet block, (b) concept (c) placement of the sixth port (d) remote box.
Grahic Jump Location
Servo valve exit port pressure
Grahic Jump Location
Force-pressure calibration with a load cell
Grahic Jump Location
Frequency response of servo valve (Frequency in rad/s)
Grahic Jump Location
Response of simulated control system
Grahic Jump Location
Response of the actual system with PI controller (Desired pressure=1.7 bars, disturbance at 1 second by another valve)
Grahic Jump Location
AirGlove-VADE Communication architecture
Grahic Jump Location
Mean and standard deviation of task completion times in all experiments

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In